MRI MACHINE DEALER, SALES & SERVICE IN BANGALORE, KARNATAKA


Biomed Technology is a professional company incorporated to promote high quality, cost effective MRI Scanner Sales, Service and Repair. Our team has extensive experience of over 10 years in medical imaging service industry and installed all over India and sales to world.


TOP MRI SCAN MACHINE REPAIR & SERVICES IN BANGALORE

Biomed Technology is one of the MRI machine Wholesale Trader from Bangalore, we offer refurbished mri machine, preowned mri machine, hitachi mri machine, siemens mri machine, ge mri machine, toshiba mri machine, philips mri machine. MRI scan machine is most useful for scanning the brain and spinal cord. It is also used to scan the chest, abdomen, blood vessel and bones. MRI scan machine helps to diagnose various medical conditions and diseases. MRI scan detects any abnormalities such as tumors, infection, injury, bleeding or diseases of the blood vessels.


REFURBISHED MRI MACHINE SALES & MAINTENANCE

Biomed Technology specialized in sales, service for MRI machines are Siemens, Philips, Hitachi, GE and Toshiba. In addition to the innovative service and parts solutions we can assist you from end to end on your imaging project requirements including system purchase, site planning, relocation, installation and applications. Our clients range from big and small hospitals, nursing homes, diagnostic centers and individuals running diagnostic facilities. MRI models are
SIEMENS:MAGNETOM Spectra 3T, MAGNETOM Symphony 1.5T, MAGNETOM Avanto 1.5T, MAGNETOM Concerto, MAGNETOM C!
GE: SIGNA HD 1.5T (SUPERCON MAGNET), SIGNA HDxT 1.5T(SUPERCON MAGNET), SIGNA EXCITE 1.5T(SUPERCON MAGNET)
HITACHI:Echelon 1.5T, Airis I(PERMANENT MAGNET), Airis II(PERMANENT MAGNET), AIRIS ELITE(PERMANENT MAGNET), AIRIS VENTO(PERMANENT MAGNET)
TOSHIBA:Vantage titan 3T, Vantage AGV 1.5 T (SUPERCON MAGNET)
PHILIPS:Discovery MR750 3T, SIGNA HD 1.5T (SUPERCON MAGNET)


MRI MACHINE SALES SERVICE IN BANGALORE, INDIA

MRI(Magnetic Resonance Imaging) machines have a scanning technique to generate a detailed image of body. It is used in the field of diagnosis. That means, diagnose many disorders like strokes, tumours, aneurysms, spinal cord injuries, multiple sclerosis etc. It is a fast and useful innovation that helps medical professionals study body anatomy and body parts that is of interest. The scanner depends on biological parameters like longitudinal relaxation time(T1), variable image contrast, proton density & transverse relaxation time(T2) that are obtained by utilizing variable pulse sequence and changing imagining parameters. Signal intensities T1 & T2 allows superb contrast between different soft tissues.



MAGNETOM Spectra 3T



SPECIFICATION              PARAMETER 
Brand Seimens MODEL MAGNETOM Spectra Field Strength 3 Tesla Bore diameter 60 cm Total bore length with covers 173cm Overall gantry dimensions H x W x L(m) 2.19 x 2.31 x 4.61 Gantry weight 7,350 (16,204) Scanning,(kW) 17.2 Standby,(kW) 7.4 Standard strength, z-axis 33 mT/m Standard slew rate, z-axis 125 t/m/sec Minimum equipment room size <31 m2 Helium consumption Zero Helium boil-off technology

MAGNETOM Symphony 1.5T



SPECIFICATION               PARAMETER 
Brand Siemens MODEL MAGNETOM Symphony ELECTROMAGNETIC FIELD STRENGTH 1.5 Tesla LINE VOLTAGE, VAC 380/400/420/440/480 Kva 50 CLINICAL USE Whole body Body coil (DIAMETER) 60 cm Head coil (DIAMETER) 26 ID Inversion time, msec (IMAGING) 22 Slice thickness,mm (GANTRY) 0.1-200 (2-D), 0.05-20 (3-D) Fov, cm 0.5-50 Fov offsets ±25 Cooling method Single cryogen, 2stage refrigeration MAGNET WEIGHT(kg) 4,050; 5,500 in operation

MAGNETOM Avanto 1.5T



SPECIFICATION               PARAMETER 
Brand Seimens MODEL MAGNETOM Avanto Field Strength 1.5 Tesla Magnet Superconducting LINE VOLTAGE, VAC 380/400/420/440/480 Kva (POWER NEEDED) 90 MAGNET WEIGHT(kg) 3550 Strength, mt/m 3535/57; 45/76 Rise time to 10 mt/m, msec SR 346 T/m/s Slice thickness, mm(GANTRY) 0.1 (2-D)/0.05 (3-D) Fov, cm (IMAGING) 0.5-50 Fov offsets (IMAGING) ±25 Cooling method(X-RAY TUBE) Single cryogen Liquid helium (CRYOGEN USE, L/hr) Yes DIMENSIONS (HXWXD),CM (CRYOGEN USE, L/hr) 230 x 229.5 x 405

MAGNETOM Concerto



SPECIFICATION         PARAMETER 
Brand SIEMENS MODEL MAGNETOM Concerto MAGNET PermanentC-shaped LINE VOLTAGE(VAC) 380/400/420/440/480 POWER NEEDED(Kva) 15 MAGNET WEIGHT(kg) 11500 DIMENSIONS(HXWXD),CM 193 x 120 x 195 ELECTROMAGNETIC FIELD STRENGTH(T) 0.2 Homogeneity 4.0 ppm @ 36 cm DSV Fov, cm (IMAGING) 0.5-40 Body coil (cm) 78.7, 96.5, 116.8, 127; 4 coils Head coil (cm) 21 x 21 Slice thickness(mm) 1.7 (2-D), 0.05 (3-D)
  • magnetom_c!

MAGNETOM C!



SPECIFICATION         PARAMETER 
Brand SIEMENS MODEL MAGNETOM C! MAGNET Open bore - vertical/upright LINE VOLTAGE(VAC) 380,400,420,440,480 V POWER NEEDED(Kva) 15 Bore size 270° accessibility DIMENSIONS(HXWXD),CM 137(W) + 209(D) + 189(H) ELECTROMAGNETIC FIELD STRENGTH(T) <0.59 Magnet field strength 0.35 Tesla Homogeneity <4 Fov, cm (Min, Max) 0.5-40 Gantry_Styles Open_C Shaped COOLING SYSTEM Air Channel 4 ch

SIGNA HD 1.5T (SUPERCON MAGNET)



SPECIFICATION          PARAMETER 
No. of Channels 8, 16 Software Versions 12X Tyoe Of Magnet CXK-4 Helium Boiloff Zero Boiloff Magnet Weight 5300kg DIAMETRE 60CM FOV 48CM Gradient Amplitude 33mT/m Slew Rate 120mT/sec Speacial Application GRE,SPGRE,FGRE,FSPGR, MRCP/2d cine Angiography LAVA, Propellar. Tricks, DTI, Enhance, Inhance Recommended 15-25 cases Magnet field strength 1.5 Tesla

SIGNA HDxT 1.5T(SUPERCON MAGNET)



SPECIFICATION          PARAMETER 
No. of Channels 8, 16 Software Versions 12X Tyoe Of Magnet CXK-4 Helium Boiloff Zero Boiloff Magnet Weight 5300kg DIAMETRE 60CM FOV 48CM Gradient Amplitude 33mT/m Slew Rate 120mT/sec Speacial Application LAVA, Propeller, Cube T2 Tricks, IDEAL, Enhance, SWAN, Perfusion, Non-contrast, Angiom, DTI, probe - 2000 Recommended 20-30 cases

GE SIGNA EXCITE 1.5T(SUPERCON MAGNET)



SPECIFICATION           PARAMETER 
No. of Channels 8 Software Versions 11X Tyoe Of Magnet CXK-4 Helium Boiloff Zero Boiloff Magnet Weight 5300kg DIAMETRE 60CM FOV 48CM Gradient Amplitude 33mT/m Slew Rate 120mT/sec Speacial Application GRE,SPGRE,FGRE,FSPGR, MRCP/2d cine Angiography LAVA, Propellar. Recommended 10-15 cases Internal Auditary Canal 3D Fiesta

Echelon 1.5T



SPECIFICATION      PARAMETER 
Brand Hitachi MODEL Echelon 1.5T Magnet Configuration Closed bore - short(<1.5 meters) Gantry_Styles Short bore horizontal field Magnet field strength 1.5T Tesla Gradient Strength 30 m T/M FOV (Min, Max) 3-50 cm Magnet cooling type Cryogen - Cold head Cryogen use 1 refill every six years L/hour Table weight limit [lbs] 500 Unit dimensions with service space 220cm x 210cm x 160cm(HWD)gantry Power requirements (VAC, Amps) 3 phase AC 380, 400, 415V 50 Hz 3 phase AC 460, 480V 60 Hz Installed weight 5150 kgs fully installed gantry

Airis I(PERMANENT MAGNET)



SPECIFICATION      PARAMETER 
Brand HITACHI Tesla 0.3 Tesla Magnet Permanent Magnet Type Open Type Gradient Strength 8mT/m Slew Rate 11mT/m/Sec Channel 2 ch Gap 43 cm V Monitor type CRT Dicom Option Optional Power Supply10 KVA Recommended Below 15 Cases

Airis II(PERMANENT MAGNET)



SPECIFICATION      PARAMETER 
Brand HITACHI Tesla 0.3 Tesla Magnet Permanent Magnet Type Open Type Gradient Strength 21mT/m Slew Rate 55mT/m/Sec Channel 4 ch Gap 42.5 cm V Monitor type TFT(LCD) Dicom Option inbuilt Power 10 KVA Recommended Below 25 Cases

AIRIS ELITE(PERMANENT MAGNET)



SPECIFICATION      PARAMETER 
Brand HITACHI Tesla 0.3 Tesla Magnet Permanent Magnet Type Open Type Gradient Strength 21mT/m Slew Rate 55mT/m/Sec Channel 4 ch Gap 42.5 cm V Monitor type CRT(LCD) Dicom Option inbuilt Power 10 KVA Recommended Below 25 Cases

AIRIS VENTO(PERMANENT MAGNET)



SPECIFICATION             PARAMETER 
Brand HITACHI MODEL Airis Vento Design Assymetric Two-pillar FIELD STRENGTH(T) 0.3 Tesla opening to the front 210(deg) opening to the rear 70(deg) Installation < 25 m2 Lateral table movement ±100 mm patient table Fully motorised gradients 22mT/m 55T/m/s Average power consumption 2.5kw

Vantage titan 3T



SPECIFICATION            PARAMETER 
Brand Toshiba MODEL Titan 3T Bore diameter at Isocenter(cm) 71 aperture,69 bore diameter Total bore length with covers(cm) 163 magnet, 175 with covers Gantry dimensions, H x W x L(m) 2.4 x 2.62 x 2.28 Scanning(kW) 71/hr Dimensions, L x W(cm) 242 x 57.5 Channel options 16, 32 Power output(kW) 36 Receiver bandwidth(kHz) 1,000 CLINICAL USE Whole body Cryogen refill frequency >=10 years (zero boil-off) Standard strength, z-axis, mT/m 30 Standard slew rate, z-axis, t/m/sec 203

Vantage AGV 1.5 T



SPECIFICATION              PARAMETER 
Brand Toshiba MODEL Vantage AGV MAGNET Superconducting ELECTROMAGNETIC FIELD STRENGTH 1.5 T LINE VOLTAGE, VAC 380/400/415/440/480 Kva (POWER NEEDED) 35 CLINICAL USE Whole body Slice thickness,mm(GANTRY) 0.5 minimum 2 DFT, 0.05 minimum 3 DFT Fov, cm (IMAGING) 0.5 DIMENSIONS (HXWXD),CM (CRYOGEN USE, L/hr) 241 x 201 x 179 Strength, mt/m 30 Rise time to 10 mt/m,msec 0.2 Body coil (DIAMETER, cm) 60 Head coil (DIAMETER, cm) 27

Ingenia 3T



SPECIFICATION            PARAMETER 
Brand Philips MODEL Ingenia 3T Magnetic Strength 3 Tesla Machine Type Closed Bore Size 70 cm Max. Amplitude 45 mT/m Max. Slew Rate 200 T/m/s Magnet Weight 4600 kg Maximum FOV 55 cm Max scan matrix 1024 (2048 optional) Highest in-plane resolution 5 µm Tunnel diameter at both ends 95 cm Maximum weight capacity 250 kg (550 lbs) Total gantry installed weight ≤ 5800 kg

Achieva 1.5T



SPECIFICATION            PARAMETER 
Brand Philips MODEL Achieva MAGNET CONFIGURATION Short-bore cylindrical Bore diameter/height of patient opening(cm) 110 Overall bore length(cm) 157 Overall gantry dimensions W x H x L,(m) 2.2 x 2.1 x 1.8 Total weight w/cooling, shielding, gradient/body coil, kg (lb) 6,380 (14,065) LINE VOLTAGE, VAC 480 Kva (POWER NEEDED) 100 Optional channel configurations(RF SYSTEM) 16, 32
Experience the difference of using a C-arm designed for the specific needs in Orthopedics. The power to penetrate dense anatomy in lumbar and hip regions in small or large patients. The precision to accentuate boney anatomy for clear spine and ortho images. The performance to get the image you need in less time and with fewer exposures.